HE3DA 1 kWh battery cell with 1.7 mm electrode thickness
Basic technical parameters
Nominal voltage: .....................................................................3,7 V
Minimum discharge voltage (cut off): .......................................2 V
Maximum charging voltage (cut off): .................................4.2 V
Recommended voltage range: ................................2,5-4,1 V
Nominal capacity: ...........................................................270 Ah
Nominal energy: ..........................................................1000 Wh
Maximum charging peak current
in the discharged state:....................................................................300 A
Recommended continuous charging current: .......................30 A
Maximum charging peak current
when charged:....................................................................1000 A
Recommended continuous discharge current:.........................80 A
Life Cycle @ 10% DOD: ...........................>100000 cycles
Life Cycle @ 100% DOD: ................................1000 cycles
Temperature Range: ......................................................-10°C to 80°C
Battery response rate
to current fluctuations +80A to -80A: ...................................40 ms
Benefits
HE3DA technology
01
Safety
02
Simple battery management
03
Universal use of HE3DA batteries
04
Large cell design
05
Recyclability