Battery with a capacity of
1 kWh

Basic technical parameters

 
Nominal voltage: .....................................................................................................................3,7 V
Minimum cut-off voltage: .....................................................................................................2 V
Maximum cut-off voltage: ................................................................................................4,2 V
Recommended voltage range: ...........................................................................2,5-4,1 V
Nominal capacity: ..............................................................................................................270 Ah
Nominal energy: ............................................................................................................1000 Wh
Maximum charge peak current in discharged state:.................................300 A
Recommended continuous charging current: ..................................................30 A
Maximum discharge peak current in charged state:...............................1000 A
Recommended continuous discharging current:............................................80 A
Lifecycle @ 10% DOD: ...............................................................................>100000 cycles
Lifecycle @ 100% DOD: .....................................................................................1000 cycles
Temperature range: ..........................................................................................-10°C to 80°C
Battery response rate + 80A to -80A: ...................................................................40 ms